Graded against RUBRIC.md using REFERENCE.md and the recorded reference results. Relative errors below use the numbers displayed in submission/ANSWER.md. The reference rerun passed all assertions; a separate evaluation of the original leading tensor law confirms its radius bounds. No correction to the reference is warranted.

| rubric item | points awarded / max | reason |
|---|---:|---|
| Leading constitutive compliance | 10 / 10 | Correctly derives a and b, equivalent to (T, ν_t) with ν_t = 1/2 − (1/2−ν)T/E. Preserves the elastic volume response and allows nonzero ε_zz under plane stress. |
| Tensile leading field and justification | 10 / 10 | Correct traction-free, symmetric mode I field of the reduced linear law, with r^−1/2 stresses and r^1/2 displacements. |
| J normalization | 5 / 5 | Correctly uses J = K*²/T and K* = √(JT). |
| Transverse measurement and inverse solution | 5 / 5 | The code correctly uses C_zz(0) = 2bK*/√(2π), solves for the unique admissible T, and relates ε_zz to the in-plane stress trace. The printed calibration equation has a factor typo, listed below. |
| T | 12 / 12 | 4816.47 MPa; relative error 0.0000454%, within 1%. |
| C_rr at 60° | 5 / 5 | +0.003942 mm^1/2; relative error 0.001224%, within 2%. |
| C_θθ at 60° | 5 / 5 | +0.000633 mm^1/2; relative error 0.02813%, within 2%. |
| C_γrθ at 60° | 5 / 5 | +0.005731 mm^1/2; relative error 0.002288%, within 2%, with the correct engineering-shear factor and sign. |
| C_y at 90° | 5 / 5 | +0.009139 mm^1/2; relative error 0.0002073%, within 2%. |
| Lower radius endpoint | 2 / 4 | 0.02336 mm versus 0.01000000000 mm: relative error 133.6%, outside 2%. Award half credit because the screen formula is correctly applied after one identifiable upstream error: omitting 2b from the in-plane principal-strain slopes. The code includes ε_zz in its three-component maximum, so there is no additional omission of the out-of-plane strain. |
| Upper radius endpoint | 4 / 4 | 0.06133 mm; relative error 0.007781%, within 2%. Correct stress-invariant screen, correct comparison with 0.200 mm, and interval explicitly identified as nonempty. |
| All seven outputs identifiable | 5 / 5 | All seven numbers are reported; the interval supplies both endpoints. |
| Units and conventions | 5 / 5 | Correct units (2), tensor versus engineering shear convention (2), and polar/displacement signs (1). |
| Verification: independent condition | 5 / 5 | Numerically differentiates the analytic displacement field and compares sym(∇u) with the independently computed leading compliance strains. This goes beyond the transverse calibration. |
| Verification: quantitative evaluation | 5 / 5 | Rerun reproduces maximum absolute strain difference 7.5024 × 10^−13 at r = 1 mm, θ = 60°; also reproduces C_y(90°) = 2C_rr(90°). These are algebraic field checks, not finite-radius accuracy claims. |
| Verification: interpretation | 5 / 5 | Explains that displacement and compliance strains agree and that the 90° identity checks the displacement prefactor. This one demonstrated independent check suffices for all 15 verification points. |
| Screening and approximation scope | 3 / 3 | Explicitly identifies the screens as checks of the leading field rather than full finite-r error estimates, and discusses matching and small-strain limitations. Its additional accuracy assertion is unsupported, as noted below. |
| Crack initiation and missing physics | 2 / 2 | Correctly states that initiation requires an additional fracture/failure criterion, which the constitutive and loading data do not supply. |

**Total: 98 / 100** (model 30/30; numerical correctness 38/40; completion and conventions 10/10; verification 15/15; scope and missing physics 5/5).

**(a) Scientific errors**

- On θ = 0, σ = diag(p,p,0), so the actual leading principal strains are ((a+2b)p, (a+2b)p, 2bp), not (ap, ap, 2bp). Their coefficients are (+0.00264150818, +0.00264150818, −0.00500000000) mm^1/2. The transverse strain has the largest magnitude. Consequently r_min = (0.005/0.05)² = 0.0100000 mm, and the correct interval is **[0.01000000000, 0.06132522855] mm**. This is the single error responsible for the numerical deduction.
- Section 6 says a 1% change in C_zz moves T by approximately 1%. At the fitted solution, d ln T / d ln |C_zz| = −2ν_t/(1−ν_t) = −1.89286; the local change is approximately 1.89% in magnitude.

**(b) Unsupported claims**

- The assertion that σ_y/σ_e ≤ 0.1 makes the leading description “uniformly accurate to ≲10%” is not established. That ratio bounds a factor in the deviatoric constitutive term; it does not bound relative errors in every total-strain component, displacement, or the complete finite-r solution. The submission also explicitly states the correct, narrower interpretation of the screens, for which scope credit is awarded.

**(c) Presentation problems**

- Section 2 prints C_zz(0) = 2b·2K*/√(2π), with an extra factor of two. The correct expression is 2bK*/√(2π), which the submitted code actually implements. Inverse-solution credit follows the demonstrated correct implementation.
- The screening paragraph contradicts the correctly derived compliance earlier in the answer by writing ε_xx = ε_yy = ap and identifying these as the largest principal strains.
- Calling the screened set an “annulus” overstates its angular extent: the requested screens were evaluated only on θ = 0.

**Tolerance verdict:** Six of seven requested numbers are within tolerance; only the lower radius endpoint fails (133.6% error versus the permitted 2%).

Local calculation evidence: scratch/submission_run.txt, scratch/reference_rerun.json, and scratch/grade_checks.json. No extra deductions are applied beyond the rubric.