| rubric item | points awarded / max | reason |
|---|---:|---|
| Governing model and physical justification | 8 / 8 | Correct antiplane equilibrium and displacement compatibility with the supplied pure nonlinear shear law; the stress formulation is equivalent to the reference formulation. |
| Admissible local radial behavior | 8 / 8 | Derives the stress exponent from nonzero finite flux, J ∝ r^[1−p(n+1)], giving p = 2/9 and displacement exponent s = 1−np = 2/9. Shooting independently reproduces this exponent. |
| Symmetry, traction-free faces, positive slip | 6 / 6 | Implements odd displacement, T_θ(π) = 0, and positive upper-face displacement; both requested stresses have the correct signs. |
| Magnitude fixed by J | 8 / 8 | Uses W = n/(n+1) τ·γ and both terms of the prescribed flux. Rerun gives I_n = 2.019595277 and A_T = 64.193241 MPa·mm^(2/9). |
| Δw at 0.0200 mm | 8 / 8 | Submitted +0.0013181 mm; relative error 0.002032%, within 2%. |
| Δw at 0.0800 mm | 8 / 8 | Submitted +0.0017937 mm; relative error 0.000349%, within 2%. |
| Signed τ_rz at 0.0200 mm, 60° | 6 / 6 | Submitted +38.59 MPa; relative error 0.008819%, within 2%. |
| Signed τ_θz at the same point | 6 / 6 | Submitted +138.0 MPa; relative error 0.007693%, within 2%. |
| Engineering-shear contour radius at 0° | 4 / 4 | Submitted 0.04689 mm; relative error 0.009432%, within 2%. |
| Engineering-shear contour radius at 90° | 4 / 4 | Submitted 0.02507 mm; relative error 0.015465%, within 2%. |
| Engineering-shear contour radius at 180° | 4 / 4 | Submitted 0.01340 mm; relative error 0.011893%, within 2%. |
| All seven numerical outputs identifiable | 5 / 5 | All seven requested quantities are clearly tabulated. |
| Correct units | 2 / 2 | Displacements and radii use mm; stresses use MPa. |
| Engineering versus tensor shear | 2 / 2 | Uses γ = ∇w and its vector magnitude without a factor-of-two error. |
| Face-limit convention | 1 / 1 | Explicitly labels the 180° contour intersection as a face limit and evaluates the interior angular field there. |
| Verification addresses a genuine requirement | 5 / 5 | Checks the independently known n = 1 solution, face traction, and energy flux. |
| Verification supplies numerical evidence | 5 / 5 | Rerun gives face residual 1.27×10^−16, linear-limit slip relative error 9.99×10^−16, and J = 0.120000 N/mm on all four reported circles. |
| Verification interprets agreement | 5 / 5 | Explains agreement with the exact linear solution, zero face traction, and supplied J; these checks suffice independently of the additional equilibrium claim discussed below. |
| Recognition of missing fracture physics | 5 / 5 | Correctly states that initiation requires an additional material failure criterion, such as critical J or a damage rule. |

**Total: 100 / 100.** Category totals: model 30/30, numerical correctness 40/40, completion and conventions 10/10, verification 15/15, missing physics 5/5.

Both the unchanged submission copied into `scratch/` and the reference code ran successfully. The reference's two independent routes agree; no reference error was found. Rerun evidence is retained in `scratch/submission_run.txt`, `scratch/reference_run.json`, and `scratch/tolerance_audit.json`.

(a) Scientific errors

- None identified in the governing field, normalization, requested outputs, or fracture-initiation conclusion.

(b) Unsupported claims

- The extra Cartesian equilibrium check refers to “sample points,” but the supplied code checks only (0.03, 0.02) mm. Its claimed relative bound is supported under normalization by the sum of derivative magnitudes, as explained below; broader sampling is not demonstrated. This does not reduce verification credit because the other sound quantitative checks already meet all three rubric requirements.

(c) Presentation problems

- The normalization of the claimed equilibrium residual ≤7×10^−6 is unspecified. The rerun gives |div τ| = 1.736×10^−2 MPa/mm: approximately 1.10×10^−5 relative to one derivative term, or 5.48×10^−6 relative to the sum of their magnitudes. The requested quantities and conventions are otherwise clear.

**Tolerance verdict:** All seven requested signed numerical values are within the stated 2% relative tolerance; the largest submitted-answer error is 0.015465% (the 90° contour radius).