Read the mechanics: model and solutionSee how the agents did
Detournay and Cheng (1991) loaded a stationary crack in a Biot solid by a sudden face traction or a sudden face pore pressure. We gave their problem, without the paper, to AI agents. Most answers recovered the crack-scale elastic limits. The decisive step was the crack tip, where the solid drains at once even though the crack as a whole responds undrained.
To see whether agents select the right physical limit at a singular point, carry it through to every requested quantity, and check what they report against the problem they were given.
Given only the governing equations and the two loadings, can an AI agent find the stress intensities and crack volumes at short and long times, including the tip intensity just after loading and the leading growth of the volume?
Every run in the comparison found the crack-scale limits: the undrained and drained volumes and the long-time intensity. The difference was at the tip. GPT, in three of three runs, and Opus 5.5, in its single run, treated the tip as drained inside an undrained outer field and obtained K₁(0⁺) = 0.8076√(πL). Every other run took the crack-scale value √(πL) at the tip, and with it missed a tip term in the volume growth as large as the face term.
Loading 2 separated the runs a second time. Its long-time state is a pressurized region still confined by the solid around it, which closes the crack with a back-stress −η. Most other answers treated the region as free to swell (zero) or replaced it by an effective face traction (−α).
drained tip 3/3 full volume 2/3 loading 2 3/3
A Fourier–Laplace formulation that kept both limits; 9, 9 and 8 of 9 values. One run kept the faces-only volume term.
drained tip full volume loading 2
A Laplace-domain coupled solver; states both orders of limits. 9 of 9 values; Grok: correct.
tip 0/3 loading 2 0/3
Outer elastic values right; tip zones judged higher order; loading 2 taken as free swelling. 4, 5 and 5 of 9.
tip 0/2 faces term 1/2 loading 2 0/2
Max found the full face term by reciprocity; both used −α for loading 2. 5 and 5 of 9; Grok: partial.
tip 0/3 loading 2 1/3
One run found the confined back-stress by an inclusion argument; all took the elastic tip. 7, 5 and 5 of 9.
tip 0/3 loading 2 0/3
Elastic tip in all runs; loading 2 set to zero or to an effective face traction. 5, 4 and 5 of 9.
All runs recovered the undrained start and the drained end at the crack scale. Four runs, three by GPT and one by Opus, found the drained-tip value (MP-39 called its own value provisional); the others reasoned with elasticity at one modulus at a time.
Two limits, not one. The short-time limit ct/L² → 0 makes the crack scale undrained, but the tip is drained at every positive time because its own drainage time r²/c is zero. Only the runs that kept r/√(ct) as a second variable found the tip value and the tip volume term.
A correct global argument applied at the wrong scale gave confident, internally checked answers. The checks reproduced the assumption and could not catch it.
A stationary crack of length 2L lies in an infinite, isotropic Biot solid in plane strain. The pores are filled with fluid that flows by Darcy’s law. Stress and pore pressure couple in both directions: compressing the solid raises the pore pressure, and pore pressure strains the skeleton.
Two time scales matter. If the load changes faster than fluid can move, the fluid content of each material point is fixed and the solid behaves elastically with the undrained Poisson ratio νu. Once the pore pressure has diffused away it behaves elastically with the drained ratio ν. Diffusion over a distance ℓ takes a time ℓ²/c, so after a time t the drained region extends about √(ct) from any drained boundary.
Two loadings act on both crack faces from t = 0. In loading 1 the faces carry a unit pressure and are kept drained, p = 0. In loading 2 the faces carry no traction but a unit pore pressure. The task asked for K and the crack volume V at t = 0⁺ and as t → ∞, the leading growth of V at small times, and the pore pressure induced next to the faces, for ν = 0.2, νu = 0.4 and α = 0.89.
As in the paper Model, loadings and material values from Detournay and Cheng (1991), Eqs. 1–10 and p. 1655, as given to the agents.
Evidenceproblem as given · key, source table
The crack-scale limits. A sudden load meets an undrained solid, so the opening is the Griffith ellipse with νu and the volume is π(1 − νu)L²/G. The change in mean stress raises the pore pressure next to the faces to 2(νu − ν)/[α(1 − 2ν)]; on the faces themselves p = 0 is prescribed. At long times the solid is drained: the volume is π(1 − ν)L²/G and the intensity under unit traction is the Griffith value √(πL), which contains no material constant.
The tip. The requested intensity is taken at the tip at fixed positive time, and then t → 0⁺. The induced pore pressure has unbounded gradients at a permeable tip, so within r ≪ √(ct) the tip is drained, however small t is. The drained tip field has to be matched to the undrained crack-scale field through the diffusion layer. In the Laplace domain this is a 2 × 2 Wiener–Hopf problem whose symbol depends only on ηt = (νu − ν)/(1 − νu), here 1/3. Its factorization gives K₁(0⁺) = 0.807593√(πL).
The paper’s simplified solution, 0.75 = 1/(1 + ηt), puts the undrained opening into the drained intensity formula; in the factorization this sets the matching factor n11 to 1. Taking t → 0 first at fixed r gives the outer value 1 instead. For gels (νu = 0.5), Yu et al. (2020) write the tip limit as [(1 − νu)/(1 − ν)]m with m ≈ 0.735 (their α, not the Biot coefficient); for this material the factorization corresponds to m ≈ 0.743 (our reading).
The volume growth. A reciprocal identity with the undrained slit solution turns the volume change into an integral of the fluid content against that solution’s stress trace. Along the faces, one-dimensional drainage layers give the paper’s term, 1.354055. Near each tip the drained region shrinks like √(ct), but the trace is singular there, so the tips contribute at the same √t order: 1.086165, from the same factorization. The coefficient is A = 2.440220.
Loading 2. A step in face pore pressure moves nothing at t = 0⁺, so K₂(0⁺) = 0. At long times the pressurized region around the crack is still confined by the infinite solid around it. It carries a uniform confining stress −η, which acts on the faces as a back-stress and closes the crack.
Corrected key Crack-scale and loading-2 results from the paper (Eqs. 13–39); tip intensity and tip volume term from two factorization reviews, checked at lower precision by finite elements and, for the tip volume term, by a direct solve on 29 October.
Evidencekey with its correction table · Codex factorization, 0.8075930 ± 0.000002 · Grok’s separate factorization, 0.80759 ± 0.00005 · factorization rerun on 25 October, identical to the saved output · finite elements, 0.80 ± 0.01 · closed forms · formula check · independent check of the tip volume term, 29 October
After a time t, fluid near the tip has drained over a distance of about √(ct); farther away it has not had time to move. The tip therefore sits in a small drained region, which is more compliant, inside an undrained solid, which is stiffer. The calculation solves the problem of this transition region and compares the crack opening at its two ends, just behind the tip and far behind it. That ratio, corrected for the change in compliance, is K₁(0⁺)/√(πL).
The work is done in the Laplace transform of time, with variable s, where the drained distance becomes δ = √(c/s); small times are large s.
By symmetry only the upper half-plane y > 0 is needed, and everything that matters lies on its edge, the crack line y = 0. A Fourier transform along the line (wavenumber ξ, k = |ξ|) solves the equations off the line exactly. It leaves four quantities on the line: the opening ŵ, the normal stress Ŝ = σ̂yy, the pore pressure p̂₀, and the pressure gradient across the line Q̂ = ∂p̂/∂y, so that the fluid flux across it is −κQ. Their exact relations are in the box; C is the drained stiffness of the line, and b and β are coupling constants.
On the crack the faces carry the unit pressure and are drained: S = −1 and p₀ = 0. Ahead of the tip, symmetry gives no opening and no flux, w = 0 and Q = 0, while the stress and the pressure there are unknown. The kind of condition switches at the tip, and that switch is what makes the problem hard.
The bracket carries the physics. For wavelengths much longer than δ (k ≪ √(s/c)) the fraction (m − k)/(m + k) tends to 1, and the stiffness is C(1 + ηt) = G/[2(1 − νu)], the undrained value. For wavelengths much shorter than δ it tends to 0, and the stiffness is C, the drained value. Long waves are the crack scale; short waves are the tip.
Codex’s review, Eq. (1): VERDICT.md, lines 30–100; the algebra is checked symbolically in analytic_checks.py. The two limits of the bracket follow from the equation itself.
Near a tip at small times the only length is δ. Distance from the tip is measured in units of δ, X = (x − L)/δ, and wavenumbers in units of 1/δ; from here on ξ, k and m are these scaled quantities, so m = √(1 + ξ²). Far behind the tip the opening must join the undrained crack field, which opens as the square root of the distance; it is normalized to √(−X) there.
The relations of step 1 then become one matrix equation. A 2 × 2 matrix N(ξ), in the box, acts on the opening and the flux, which are nonzero only on the crack (X < 0), and gives the stress and the pressure, which are unknown only ahead of the tip (X > 0), once known scalar factors are taken out. N depends only on ηt.
Its two ends are the two solids of step 1: N(0) = diag(1 + ηt, 1) is the undrained solid, at wavelengths long compared with δ, and N(∞) = I is the drained solid, at short ones. The off-diagonal terms, proportional to √(2ηt), couple deformation and flow; they vanish at both ends.
VERDICT.md, lines 123–151 (Eq. 4); the same matrix is built in wilson_factor.py, lines 21–26.
An equation whose conditions switch at a point is solved by splitting its matrix into two factors, N = N₊N₋, one belonging to each side of the tip. In mathematical terms, each factor and its inverse are analytic in one half of the complex ξ-plane; the split exists because N is Hermitian and positive definite, like a stiffness.
The equation can then be rearranged so that one side contains only quantities on the crack and the other only quantities ahead of it. Both sides must equal the same simple function, which gives the solution without computing the fields everywhere. Requiring both factors to become the identity at short wavelengths, the drained tip, makes the split unique.
N₋ at zero wavenumber, the undrained far field, gives two numbers (box).
n₁₁ is the amplitude of the opening just behind the tip, w ≈ n₁₁√(−X), when the opening far behind is √(−X). n₂₁ is the amplitude of the pore pressure around the tip, p ≈ −√(2/ηt) n₂₁ √R cos(θ/2), where R (in units of δ) and θ are polar coordinates around the tip, with θ measured from the line ahead of it.
VERDICT.md, lines 151–184 (Eq. 5); wilson_factor.py, lines 47–54 (the normalization at short wavelengths, and n₁₁ and n₂₁ read at zero wavenumber).
Far behind the tip the opening is the undrained near-tip opening with the crack-scale intensity Kout = √(πL); at the tip it is the drained one with Ktip (r is the distance behind the tip). By step 3 the tip amplitude is n₁₁ times the far one, which gives K (box).
If the tip carried the crack-scale intensity, the opening amplitude would rise by the compliance ratio, 1 + ηt = 4/3. It rises only by n₁₁ = 1.077, so the intensity at the tip drops to 1.077/(4/3) = 0.808 of √(πL). The tip problem contains no s, so the same factor holds at every small positive time: it is K₁(0⁺).
VERDICT.md, lines 105–118 (Eq. 3) and 186–198 (Eq. 6).
An energy balance. The transformed problem has a path-independent integral, like the J-integral, which includes a term for the energy carried by fluid flow. Evaluated at the tip and far from it, it requires the balance in the box: what flows in from the crack scale is split between elastic energy at the tip and flow. It is a balance in the transformed problem, not of energy in time. The computed values satisfy it to 7 × 10⁻¹⁴, with 13.04% in the flow term. Without the flow term, n₁₁ would be √(1 + ηt) and Ktip/Kout = 1/√(1 + ηt) = 0.866, the elastic-energy estimate of section 3.
A hand solution at weak coupling. When ηt is small, the pressure near the tip is known in closed form (box). It is zero at the tip and on the faces, and becomes the undrained singular pressure beyond the drained distance √(ct). Its amplitude gives n₂₁, and the energy balance then gives n₁₁ and K. The paper’s simplified solution gives 1 − ηt instead.
This expansion does not use the numerical factorization, so the two could disagree. They agree: the factorization’s slope, (Ktip/Kout − 1)/ηt, is −0.737 at ηt = 0.02 and −0.743 at 0.01 (rerun of 6 November), and −0.74993 at 10⁻⁴ (Codex), approaching −3/4.
VERDICT.md, lines 200–235 (Eq. 7) and 318–359 (Eq. 12 and the pressure in physical time); recomputed in tip_derivation_check.txt.
The Derivation box writes the volume change as an integral of the fluid content against Ta, the stress trace σxx + σyy of the undrained slit solution. Along the faces, fluid drains in layers about δ thick, which gives the paper’s term. Near each tip the drained region is only about δ across, an area δ², which looks negligible.
But both factors are singular there: Ta ≈ √(2L/r) cos(θ/2), and the undrained pressure, which drains there, has the same 1/√r singularity. Each is of size δ−1/2 at distances of order δ, so their product over the area δ² is of order δ, the same order as the face layers. The box computes it.
In the scaled variables of step 2, with Z proportional to the fluid content and f = R−1/2 cos(θ/2) the shape of Ta, Green’s identity, an integration by parts in two dimensions, turns the area integral into the pressure amplitude of step 3:
With the scales restored and two tips, this is the tip term of A in the Derivation box: 1.086165, beside 1.354055 from the faces.
VERDICT.md, lines 271–306 (Eqs. 10, 11).
The command in the box factorizes N on three frequency grids, of 16,384, 65,536 and 262,144 points, and extrapolates: n₁₁ = 1.0767907 and n₂₁ = 0.4169595, so K₁(0⁺)/√(πL) = 0.807593 and A = 1.354055 + 1.086165 = 2.440220. These are numerical estimates, not certified bounds.
Separately, finite elements give K₁(0⁺) = 0.80 ± 0.01, and a direct finite-crack solve gives the tip term as 1.09 ± 0.01. The review was given GPT’s answers and code, so it is an informed check, not a blind one.
From the case package (NumPy; about 8 s):
python3 grading/review_B_K10-codex/output/scratch/wilson_factor.py \
--counts 16384 65536 262144 --scales 0.01
Rerun of 6 November 2026: tip_derivation_check.txt; FE_CHECK.md; independent check of 29 October.
Just after loading the crack as a whole is stiffer than it will be: its volume starts at 1.885 and grows to 2.513 as the solid drains. The tip does not follow the crack. Its intensity starts at 0.81 of the Griffith value and rises to it as the drained region spreads.
The drop at the tip depends only on how different the drained and undrained solids are, measured by ηt. It lies between two simpler estimates. Matching elastic energy alone gives 1/√(1 + ηt), which is too high because part of the energy flux into the tip is carried by the pore-pressure field. The paper’s simplified solution gives 1/(1 + ηt); it leaves out the matching layer and falls below the full solution. At ηt = 1 the factorization gives 0.6019, against 0.5 from the simplified solution.
Loading 2 behaves differently. At long times the pore pressure near the crack tends to the face value, but only within a region of radius about √(ct) that keeps growing; beyond it the solid is unpressurized and holds the region in, like a heated inclusion in a cold plate. In two dimensions there is no bounded steady state, and the limits t → ∞ and r → ∞ do not commute. That confinement puts the region in compression, which closes the crack: K₂(∞) = −0.33375√(πL) and V₂(∞) = −0.839 L²/G. In a real fluid-filled crack this closure is superposed on loading 1.
Consequence of the solution The curve uses the same factorization code as the key; it was not part of the task.
Evidencecurve values and energy-identity residuals · script · Grok on the two bounds
The problem states the constitutive law, Darcy flow, mass balance and diffusivity exactly as in the paper, the two loadings and the material values, and asks for the nine quantities in a results file with a derivation and checks. It does not mention drainage at the tip, the order of limits or the reciprocal theorem.
# Task Solve the problem below. Budget: 50 minutes. Write `ANSWER.md` early and keep it updated, and make sure it is complete before the budget ends. You may write and run code in this folder (`python3` with numpy and scipy). **Deliver three things:** 1. **`ANSWER.md`.** Your answers, the model and method you chose and why, your derivation in brief, and what is missing or uncertain. If anything in the problem is unclear or missing, list it under "Questions" with the assumption you used, and continue. 2. **`results.json`.** It holds every quantity listed under "Report" in the problem, with the names given there (numbers as numbers, formulas as strings), plus `reproduce_command`: the command of item 3. 3. **One command that reproduces your numbers,** named in ANSWER.md (for example `python3 solve.py`). It must print the values in `results.json`. **For every check you make:** report what you compared, the output (pasted, not retyped), and how the check could have failed. Keep `PROCESS.md`: one line per step, each starting with a time pasted from `date -u +%H:%M:%S` (never type a time). Rules: use only this folder and your own knowledge. Do not open files outside this folder, and do not use web search or web fetch. The session log will be checked. Never stop or kill a process you did not start. Kill only by the PID you recorded when you started it; never use pkill, killall, or pgrep-based loops (this machine is shared with other runs). --- # Problem: a suddenly pressurized crack in a fluid-saturated porous solid An infinite, homogeneous, isotropic, fluid-saturated porous solid deforms in plane strain (x–y plane). A crack occupies −L ≤ x ≤ L, y = 0. The solid obeys Biot's linear poroelasticity, with shear modulus G, drained Poisson's ratio ν, undrained Poisson's ratio ν_u (ν < ν_u ≤ ½), Biot coefficient α (0 < α ≤ 1) and permeability coefficient κ. In terms of the total stress σ_ij (tension positive), the pore pressure p, the strain e_ij and the variation of fluid content per unit volume ζ: - 2G e_ij = σ_ij − ν σ_kk δ_ij + α(1 − 2ν) δ_ij p - 2G ζ = α(1 − 2ν) σ_kk + α²(1 − 2ν)² p / (ν_u − ν) - equilibrium: σ_ij,j = 0 - Darcy: q_i = −κ p,i - mass balance: ∂ζ/∂t + q_i,i = 0 (indices 1, 2; summation implied). The diffusivity is c = 2κG(1 − ν)(ν_u − ν) / [α²(1 − 2ν)²(1 − ν_u)]. Stresses and pore pressure are zero everywhere for t < 0 and vanish at infinity. Two loadings act on both crack faces (−L ≤ x ≤ L) for t > 0. Here σ_n = σ_yy is the normal stress on the faces and H is the unit step. - **Loading 1:** σ_n = −H(t), p = 0. - **Loading 2:** σ_n = 0, p = H(t). Let K be the mode I stress intensity factor at the crack tips, and V the crack volume per unit thickness (the integral of the opening over the crack; positive for an open crack). (a) For loading 1, find K and V just after loading (t = 0⁺) and at long times (t → ∞). Find also the leading-order growth of V at small times, ct/L² ≪ 1. (b) For loading 2, find K at t = 0⁺ and as t → ∞, and V as t → ∞. (c) Evaluate your results for ν = 0.2, ν_u = 0.4 and α = 0.89. **Report in `results.json`** (for (c); K in units of √(πL), V in units of L²/G, per unit loading magnitude): - `K1_0`, `K1_inf`, `V1_0`, `V1_inf`: loading 1 at t = 0⁺ and t → ∞; - `V1_short_coeff`: the coefficient A in V ≈ V1_0 + A √(ct/L²) for loading 1 at small times; - `p_faces_0`: in loading 1, the pore pressure induced in the solid immediately next to the crack faces at t = 0⁺, before it diffuses; - `K2_0`, `K2_inf`, `V2_inf`: loading 2; - `formulas`: your general expressions for all of the above, as strings.
From MP-37 TASK.md, the header of TASK_HEADER.md with the 50-minute budget filled in, followed by the problem. The trials of 24 October received the same problem with a shorter instruction.
The original round ran on 8 October with a 50-minute budget: three runs each of GPT-6.1 Sol, Kimi K3, GLM-5.3 and DeepSeek V4.1 Flash. The first three DeepSeek runs had reasoning switched off by a configuration error; three reasoning-on reruns replace them in the comparison. On 24 October the unchanged problem went to Kimi K3.1 Pro in fresh high and max sessions and to Opus 5.5 as a fresh sub-agent; their problem-file hashes match the original.
The paper gives a simplified solution: 0.75 for K₁(0⁺), and the face term alone, 1.354, for A. The original key took these values as exact. All three GPT runs challenged it, and the key was corrected only after a Codex factorization, a separate Grok factorization and our finite-element check agreed. The original wording “t = 0⁺” did not fix the order of the tip and time limits, so the crack-scale answer 1 receives partial credit.
| Agent | Interface and setting | Runs | Time used | Grading |
|---|---|---|---|---|
| GPT-6.1 Sol | OpenCode via Azure | 3 | 32–49 min | blind Codex grade; key checks |
| Kimi K3 | Cline via Azure | 3 | 11–22 min | blind Codex grade; key checks |
| GLM-5.3 | OpenCode | 3 | 28–55 min | blind Codex grade; key checks |
| DeepSeek V4.1 Flash | Cline via Azure, reasoning on | 3 | 15–30 min | blind Codex grade; key checks |
| Kimi K3.1 Pro | Kimi CLI, high and max | 2 | 8 and 29 min | blind A/B Grok 4.6 review |
| Opus 5.5 | Claude Code sub-agent, max effort | 1 | 94 min | Grok 4.6 review with reruns |
All three GPT runs wrote the problem in Fourier–Laplace form, where drained and undrained behaviour appear as the two ends of one transform symbol. MP-37 then defined the tip intensity explicitly, “first extract the stress singularity at each positive time, then let time tend to zero”, and noted that the opposite order gives a different number.
It solved the tip problem by a canonical Wiener–Hopf factorization and checked the factors with the identity n11² + n21² = 1 + ηt, a Laplace-domain balance of the configurational energy flux that includes its pore-pressure part (not conservation of elastic energy during the transient). Reciprocity then gave the full volume coefficient, faces and tips: 2.440220.
MP-38 reached the same values. MP-39 found the tip value, 0.807, from a collocation calculation it called provisional, but kept the faces-only volume term 1.354. Its answer names the unresolved tip matching as “the principal missing part of this answer”.
A later extension to other materials showed the limit of the delivered code: at ηt = 1 its factorization returned an exponent near 1.15, inconsistent with the trend, where the separate Wilson factorization gives K/K₀ = 0.601850. The original success did not establish a solver that works for every material.
drained tip 3/3full volume 2/3loading 2 3/3 9, 9 and 8 of 9 values.
Opus formulated the total-traction and pore-pressure boundary data as a Laplace-domain mixed problem, solved it with a Chebyshev–Galerkin method and inverted in time numerically. Its answer opens with the distinction the other agents missed: at t = 0 exactly the crack-scale value is √(πL), but for any t > 0 the tip is drained and K jumps to 0.8076√(πL), then rises.
It split the √t volume growth into the face layers, 1.354, and the tips, 1.086, and rejected a simpler “uniaxial swelling” estimate of 1.128 because it ignores the response of the body outside the layer; that is the value Kimi K3.1 high reported. For loading 2 it obtained the confined back-stress −η and noted that the long-time limits are approached only logarithmically.
Its tip intensity and tip volume term are numerical boundary-value results, reported as 0.807593 ± 0.000005 and 1.0862 ± 0.0003. Grok reran representative solver points, checked an energy identity and refitted the saved extrapolation, and graded all requested parts correct. It did not rederive every Fourier symbol or repeat the full fine-grid campaign.
drained tipfull volumeloading 2 9 of 9 values; Grok: correct. One run, longer than the others, through a different harness.
The three K3 runs started, correctly, from undrained elasticity at t = 0⁺ and drained elasticity at long times, and gave √(πL) for the tip at both. All three noticed the tip zones of size √(ct) and dismissed them: MP-24 wrote that they “contribute only O((ct)3/4) and are subleading”. That estimate keeps the singular stress but treats the fluid content in the zone as bounded. It is singular too, as r−1/2; over a zone of area ct the two singular factors give order √(ct), the same as the faces.
For loading 2 all three took the long-time pore pressure to be uniform and the solid free to swell, which gives zero intensity and zero volume. In an infinite solid with zero pressure at infinity the pressurized region stays confined.
tip 0 of 5 runsface term 1 of 5loading 2 0 of 5 K3: 4, 5 and 5 of 9. K3.1: 5 and 5 of 9; Grok: partial for both.
K3.1 Pro, in fresh high and max sessions on 24 October, kept the elastic tip value. High integrated the strain through the face layers and reported A = 1.128; max added the reciprocal response of the outer body and found the full face term, 1.354055, but not the tips. Both replaced loading 2 by an effective face traction α on a drained crack, giving −α in place of −η. Their own checks restate those reduced formulas, so they pass.
All three GLM runs gave K = √(πL) at both ends. MP-06 gave the reason: the intensity of a uniformly loaded crack is fixed by the tractions alone, for any Poisson ratio. It estimated the tip corrections to the volume as O(ct/L²) and kept a one-dimensional face-layer coefficient, 1.128.
For loading 2, MP-06 reasoned as the paper does. It described the pressurized matrix near the crack as “constrained by the far field, exactly like a hot inclusion which squeezes itself”, and obtained −η and the closing volume. The other two runs gave zero long-time intensity.
MP-06’s own numerical calculation produced K near 0.82, close to the corrected key. The record traced that number to the grid smoothing the singular pressure before any diffusion step; no refinement was supplied to tell smoothing from a converged tip limit. It was not evidence that the run had resolved drainage, and its stated answer remained 1.
tip 0/3loading 2 1/3 7, 5 and 5 of 9 values.
The three reasoning-on DeepSeek runs reported the crack-scale value 1 at the tip. MP-46 gave an explicit reason: with p = 0 on the faces, it argued, the coupling term that could make K time dependent vanishes, so the total stress, and K, are constant in time.
That argument holds at the crack scale and fails inside the diffusion layer. MP-46 also ran a transient finite-element model and read its constant drained-modulus K as confirmation. By its own calibration the model was off by 34% in volume and 43% in K, with about 40 nodes along the crack; it could not resolve a tip layer of size √(ct).
tip 0/3loading 2 0/3 5, 4 and 5 of 9 values.
For loading 2, MP-41 and MP-50 gave zero; MP-41 took the pressure to leak away to zero at every fixed point, and MP-50 took the long-time pressure to be a steady harmonic field, which it argued produces no stress. MP-46 applied the effective traction −α from the start, so its K₂(0⁺) was −0.89 instead of 0.
Placing each run by its reported values shows two clean splits. In loading 1, the four runs that took the tip to be drained sit at K₁(0⁺) ≈ 0.808; three of them also have the full volume coefficient. Every run that kept the crack-scale value at the tip also missed the tip volume term. In loading 2, only the runs that treated the pressurized region as confined reached −η.
| Step | GPT (3) | Opus 5.5 (1) | Kimi K3 (3) | Kimi K3.1 (2) | GLM-5.3 (3) | DeepSeek (3) |
|---|---|---|---|---|---|---|
| Undrained start, drained end at crack scale | 3 | yes | 3 | 2 | 3 | 3 |
| Pore pressure next to the faces | 3 | yes | 2 | 2 | 3 | 3 |
| Tip distinguished from the crack-scale field | 3 | yes | 0 | 0 | 0 | 0 |
| Drained-tip intensity 0.8076 | 3 | yes | 0 | 0 | 0 | 0 |
| Face term of A, 1.354 | 3 | yes | 0 | 1 | 0 | 0 |
| Tip term of A, 1.086 | 2 | yes | 0 | 0 | 0 | 0 |
| K₂(0⁺) = 0 | 3 | yes | 3 | 2 | 3 | 2 |
| Confined back-stress in loading 2 | 3 | yes | 0 | 0 | 1 | 0 |
| Values of 9, per run | 9, 9, 8 | 9 | 4, 5, 5 | 5, 5 | 7, 5, 5 | 5, 4, 5 |
The failures share one pattern: a correct argument applied at the wrong scale. Undrained elasticity is right for the crack and wrong for the tip; free swelling is right for a uniformly pressurized body and wrong for a confined region. The runs that solved the coupled problem directly, rather than choosing one elastic limit, did not have to choose.
Evidencevalues from each run’s saved results.json (Appendix A) · analysis of the nine original non-GPT answers · dimensional analysis of the tip condition
| Statement | Status | Basis |
|---|---|---|
| K₁(0⁺) = 0.807593√(πL), tip limit first | Checked | Codex and Grok factorizations; finite elements 0.80 ± 0.01; factorization rerun on 25 October. Both reviews had GPT’s answers and code; the finite-element route is independent of their kernel. |
| A = 2.440220, faces plus tips | Checked | The same factorizations. Finite elements, extrapolated, give 2.2–2.4: consistent, not precise enough to confirm the digits. On 29 October a direct finite-crack solve that uses no factorization values gave the tip term as 1.09 ± 0.01, and a numerical Cauchy solve within the same tip model gave 1.0861646 ± 0.00002 (report). The key keeps 1.086165; its last digits rest on the shared tip model. No grade depends on them: A is checked at 5%. |
| Crack-scale and loading-2 values | Paper, reproduced | Detournay and Cheng Eqs. 13–39; closed-form check. |
| What each run did, and its grade | AI review · expert review pending | Saved results files; blind Codex grades (same family as GPT) for the original round; Grok reviews for K3.1 and Opus. |
| Opus 5.5’s result | One run | Grok reran representative points; the run was longer and used a different harness. It does not isolate model, effort or time. |
| A new result | Not established | The same tip-limit form appears in Yu et al. (2020); two sources it cites were not read, and the tip volume term has not been compared with the literature. |
| GPT’s code for all materials | Not established | It failed at ηt = 1. |
| Finite strain, real devices | Not tested | Outside this linear stationary-crack problem. |
Each lesson rests on a handful of runs of one problem: observations to test on new problems, not measured rates.
ct/L² ≪ 1 makes the crack undrained; r/√(ct) → 0 makes the tip drained. Eleven of the fifteen runs in the comparison used the first group alone at the tip, and none of them distinguished the tip from the crack-scale field.
Section 10 table; dimensional analysis.
Several answers saw the √(ct) tip zones and judged their contribution to the volume higher order, O(t3/4) or O(t). Both the stress and the fluid content are singular there, which makes it O(t1/2), the same order as the faces.
MP-24, MP-22 and MP-06 answers.
A uniformly pressurized body swells freely; a pressurized region inside an infinite solid is held in compression. Free swelling gave zero and effective traction gave −α; the confined region gives −η.
MP-06 answer; key part (b).
K3.1’s verification scripts restated the effective-traction model and passed. A check can only catch an error it does not share.
MP-06’s 0.82 came from grid smoothing before any diffusion step. Without refinement, an apparent confirmation needed more evidence.
Correction P382.
The first key took the paper’s simplified value, 0.75, as exact, and the automatic comparison marked GPT’s full solution wrong. The key changed only after two factorizations and a finite-element check agreed, and it keeps the superseded values.
“t = 0⁺” admitted two readings. The next version of the problem states that the tip limit is taken first.
Key, “Order of limits”.
What the study does not show: that one model is better than another, that longer time or a different harness caused Opus’s result, or that the drained-tip result is new. Each would need matched, repeated runs, or a fuller literature comparison.
One problem, eighteen runs with different interfaces, budgets and repetition counts: a case study, not a ranking. The reference and the grades come from AI models and from our own finite-element calculation, and were checked by rerunning code. No expert has reviewed them.
The agents’ words quoted here come from files they saved: ANSWER.md of MP-06, MP-22, MP-24, MP-37, MP-39, MP-41 and MP-46, of Kimi K3.1 max and of Opus 5.5. Private reasoning was not used.
Every file this page links is in the case package: the task, the key and checker, every saved answer, the grades and reviews, and the records cited here. Session transcripts are not included.
Earlier records: GPT challenge case study · why the drained tip was missed · dimensional analysis · round summary · Opus’s 23 October review and corrections.
Every saved value of the eighteen graded runs, against the key as corrected on 26 October 2026. Green values agree with it within 1% (0.01 absolute for K₂(0⁺), whose key value is 0); red values do not. The checker allows 2% for K₁(0⁺) and 5% for A; its saved outputs of 26 October mark exactly the same cells, and the page build fails if they do not. Values are shown as delivered; MP-13 used a different normalization for K. The three reasoning-off DeepSeek runs are listed last. Each run links to its answer, its results file (“json”) and the checker’s output (“check”).
| Run | Agent | K₁(0⁺) | K₁(∞) | V₁(0⁺) | V₁(∞) | A | p next to faces | K₂(0⁺) | K₂(∞) | V₂(∞) | Agree |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Corrected key | 0.807593 | 1 | 1.88496 | 2.51327 | 2.44022 | 0.749064 | 0 | −0.33375 | −0.838805 | 9 | |
| MP-37 json · check | GPT-6.1 Sol | 0.807593 | 1 | 1.88496 | 2.51327 | 2.44022 | 0.749064 | 0 | −0.33375 | −0.838805 | 9 |
| MP-38 json · check | GPT-6.1 Sol | 0.808 | 1 | 1.88496 | 2.51327 | 2.44 | 0.749064 | 0 | −0.33375 | −0.838805 | 9 |
| MP-39 json · check | GPT-6.1 Sol | 0.806977 | 1 | 1.88496 | 2.51327 | 1.35406 | 0.749064 | 0 | −0.33375 | −0.838805 | 8 |
| MP-22 json · check | Kimi K3 | 1 | 1 | 1.88496 | 2.51327 | 0.56419 | 0.374532 | 0 | 0 | 0 | 4 |
| MP-24 json · check | Kimi K3 | 1 | 1 | 1.88496 | 2.51327 | 1.80541 | 0.749064 | 0 | 0 | 0 | 5 |
| MP-33 json · check | Kimi K3 | 1 | 1 | 1.88496 | 2.51327 | 1.12838 | 0.749064 | 0 | 0 | 0 | 5 |
| MP-06 json · check | GLM-5.3 | 1 | 1 | 1.88496 | 2.51327 | 1.12838 | 0.749064 | 0 | −0.33375 | −0.838805 | 7 |
| MP-10 json · check | GLM-5.3 | 1 | 1 | 1.88496 | 2.51327 | 1.12838 | 0.749064 | 0 | 0 | 0.339955 | 5 |
| MP-21 json · check | GLM-5.3 | 1 | 1 | 1.88496 | 2.51327 | 1.12838 | 0.749064 | 0 | 0 | 0 | 5 |
| MP-41 json · check | DeepSeek, reasoning on | 1 | 1 | 1.88496 | 2.51327 | 1.12838 | 0.749064 | 0 | 0 | 0 | 5 |
| MP-46 json · check | DeepSeek, reasoning on | 1 | 1 | 1.88496 | 2.51327 | 0.708982 | 0.749064 | −0.89 | −0.89 | −2.23681 | 4 |
| MP-50 json · check | DeepSeek, reasoning on | 1 | 1 | 1.88496 | 2.51327 | 1.80541 | 0.749064 | 0 | 0 | 0 | 5 |
| K3.1 high json · check | Kimi K3.1 | 1 | 1 | 1.88496 | 2.51327 | 1.12838 | 0.749064 | 0 | −0.89 | −2.23681 | 5 |
| K3.1 max json · check | Kimi K3.1 | 1 | 1 | 1.88496 | 2.51327 | 1.35406 | 0.749064 | 0 | −0.89 | −2.23681 | 5 |
| Opus 5.5 json · check | Opus 5.5 | 0.80759 | 1 | 1.88496 | 2.51327 | 2.44 | 0.749064 | 0 | −0.33375 | −0.838805 | 9 |
| MP-13 json · check | DeepSeek, reasoning off | 1.77245 | 1.77245 | 1.88496 | 2.51327 | 1.12838 | −0.118667 | 1.18311 | 1.57748 | 2.23681 | 2 |
| MP-27 json · check | DeepSeek, reasoning off | 1.25 | 1 | 1.88496 | 2.51327 | 0 | 2 | −1.25 | −1 | 2.51327 | 3 |
| MP-30 json · check | DeepSeek, reasoning off | 1 | 1 | 3.76991 | 5.02655 | 1.41796 | 1.24844 | 0 | 0 | 4.47363 | 2 |
| Version | K₁(0⁺) | A |
|---|---|---|
| Original: the paper’s simplified solution | 0.75 (Eq. 29) | 1.354055 (Eq. 18, faces only) |
| Corrected: full solution | 0.807593 | 2.440220 |
KEY.md, correction P374.
| Mesh | smallest h | K inner / K outer |
|---|---|---|
| NREF 16 | 1.1 × 10⁻⁵ | 0.7978–0.7988 |
| NREF 18 | 2.7 × 10⁻⁶ | 0.8003–0.8013 |
FEniCSx, quarter domain 20L; FE_CHECK.md. Conclusion 0.80 ± 0.01.
DeepSeek with reasoning off. The first three DeepSeek runs (MP-13, MP-27, MP-30) ran through Cline without its thinking flag, a configuration error. Their outputs include normalization and pore-pressure bookkeeping errors as well as the elastic tip. They are kept here and replaced in the comparison by three reasoning-on reruns.
Grading roles. The blind grader of the original round was Codex with gpt-6.1-sol, the same family as the GPT solver. The two factorization reviews received GPT’s answers and code, so they are informed reviews, not blind recoveries; Grok rewrote the factorization with the same kernel. The finite-element check is independent of that kernel.
Added trials. Kimi K3.1 ran through its CLI in fresh high and max sessions; the high run is shown with the max run, and both are graded partial. Opus 5.5 ran as a fresh Claude Code sub-agent with max effort recorded by the parent session; one sentence giving the workspace location was added to the same prompt. Neither trial had the 50-minute budget of the original round.